Fit wall units and rangehood before
fitting the cooktop to avoid
damaging the surface.
~
This appliance must not be
connected to a gas flue. It must be
installed and connected in accordance
with current installation regulations.
~
The room in which the gas cooktop
is installed must be at least 20 m
3
in
size with a door or window in it which
can be opened to the outside air.
~
The veneer or laminate coatings of
worktops (or adjacent kitchen units)
must be treated with 100 °C
heat-resistant adhesive which will not
dissolve or distort.
Any backmoulds must be of
heat-resistant material.
~
This equipment is not designed for
maritime use or for use in mobile
installations such as caravans, aircraft
etc. However it may be suitable for
such usage subject to a risk
assessment of the installation being
carried out by a suitably qualified
engineer.
~
An electric fryer must not be
installed directly next to a gas cooktop,
as the gas flames could ignite the fat in
the fryer. It is essential to maintain a
distance of at least 288 mm between
these two appliances.
~
A gas cooktop may not be built in
over a fridge, fridge freezer, freezer,
dishwasher, washing machine or
tumble dryer.
~
It can be installed above an oven.
The worktop must be at least 40 mm
thick.
~
Ensure that the gas pipe and
electrical cable are installed in such a
way that they do not touch any parts of
the appliance which become hot. This
could cause damage.
~
The electrical cable and any flexible
gas connection pipes must be installed
in such a way so that they do not come
into contact with any moving kitchen
parts (e.g. a drawer), and cannot
become trapped.
~
Observe carefully the safety
distances given on the following pages.
All dimensions in this instruction booklet
are given in mm.
,
This appliance must be installed
and connected to services in
accordance with local and national
safety and building regulations.