Connection to the gas supply, or conversion from one
type of gas to another, should only be undertaken by an
approved and registered gas installer in strict accordance
with current local and national safety and building
regulations.
When converting to a different type of gas, the main burner
jets and the small burner jets have to be changed.
Jet table
Main jet C Small jet C
NG
Small burner
Front medium burner
Rear medium burner
Large burner
Wok burner
0.90
1.10
1.27
1.43
1.80
0.52 (fully in)
0.52 (fully in)
0.52 (fully in)
0.60 (fully in)
0.90 (unscrewed 1 1/4 turn)
ULPG
Small burner
Front medium burner
Rear medium burner
Large burner
Wok burner
0.52
0.66
0.72
0.81
1.00
0.23 (fully in)
0.36 (fully in)
0.36 (fully in)
0.44 (fully in)
0.54 (unscrewed 3/4 of a turn )
The jet markings refer to a 1/100 mm bore diameter.
Conversion to another type of gas